Level Switches and AlarmsSingle and Multiple Point |
||
RF Admittance Types |
||
|
Delta Controls Model 103 Level Switch The Delta Controls Model 103 uses RF Admittance technology to produce switching action when a material level crosses the setpoint on its sensing probe. The Model 103 provides a 5 Amp SPDT contact, setpoint adjustment, and 1-60 second delay adjustment. Use for high reliability severe services. Electronics module is potted to withstand vibration, corrosive gases, etc.
|
||
|
Delta Controls Model 104 Tip Sensitive Level Switch The Delta Controls Model 104 top mounted probe type control switches when a conductive material touches the tip of the sensing probe. More of the sensing probe must be covered when the material is insulating and has a lower dielectric constant. The Model 104 will sense most materials such as corn, lime, dolomite, coal, water, acid, sodium hydroxide, and coffee.
|
||
|
Delta Controls Model 105 Level Switch The Delta Controls Model 105, with adjustable differential action (where the OFF setpoint is different from the ON setpoint) offers a 5 Amp DPDT contact and adjustable delay time. The electronics module can be remoted, and is potted for severe environments. The probe circuit is intrinsically safe. Used for difficult services where corrosion, heat, vibration, etc. are a problem.
|
||
|
Delta Controls Model 107 Two and Four Point Level Switches The Delta Controls Model 107 features all digital circuitry and pushbutton setup. It is potted for severe environments. An LCD display reads level directly in gallons, meters, tons, etc. Pushbutton setup and simple two point calibration means you dont have to fill or empty the tank to calibrate or recalibrate switching points accurately. The Model 107C provides two 5 Amp DPDT relays. The Model 107D provides four DPDT relays. The electronics module can be remotely mounted.
|
||
Ultrasonic Type |
||
![]() |
The Delta Controls Model 873 is an ultrasonic level controller with 2 or 4 relays for alarming or pump control.
|
|
|
Model
858 Ultrasonic Level Controller
|
||
4-20mA Input TypeThese alarms accept inputs from any 4-20mA level transmitter, such as a pressure, ultrasonic, or capacitance transmitter, and provide switching action of one or more contacts. |
||
![]() |
Delta Controls Model 341 - 4-20 mA Input Single Relay 3" Integral Module The Delta Controls Model 341 modules are configured in the 3" Integral package. They are stand alone devices which can be used as alarms or control devices. From 1 to 3 units can be mounted in a Delta housing to provide various switch sequencing functions. They may be surface mounted in user's panels and cabinets. They may also be added to housings containing 4-20 mA transmitters such as 172, 566, 592, etc. These switch points provide pump control, alarm, etc. Note that the modules are not loop powered and require a 24 VDC power source. This can be provided by the user, or from an integrally mounted power supply module (option "PS"). Specifications
|
|
|
|
Delta Controls Model 351 is a 4-20 mA Single Relay Alarm / Pump Controller The Delta Controls Model 351 is similar to the Model 341. It is configured as a stand alone device which can be mounted in various locations. It can be provided as "open frame" for mounting in enclosures by others, potted for I.S. service, mounted in 4X or explosionproof housings, and others. It can accept AC or DC supply power. It is also equipped with a built in loop power supply and has built-in diagnostic routines. Specifications
|
|
|
|
Delta Controls Model 352 - 4-20 mA Input 2 Relay Alarm / Pump Controller Two SPDT relays with individual ON and OFF setpoints. Selectable Lead/Lag pump rotation.
|
|
|
|
Delta Controls Model 354 4-20 mA Input 4 Relay Alarm / Pump Controller Four 5A SPDT relays with individual ON and OFF setpoints. Selectable pump rotation of up to 4 pumps. |
|
![]() |
Delta Controls
Model 358
Programmable Controller /
Characterizer / Re-transmitter
|
|
Conductance Switches |
||
![]() |
Model
513
- single channel
(shown) Delta Controls Conductance switches produce a switching action as a conductive material touches the tip of its sensing probe. An individual probe is required for each switch action point. Each of the switch stations may be wired for alarm action or for differential pump control action.
|
|
Mechanical Float and Displacer Switches |
||
|
|
Delta Controls builds a wide line of high reliability mechanical level switches. A float or displacer is moved up and down by variations in liquid level or interface position. One or more switch actions occur at selected level positions.
|
|
Tilt Switch |
||
![]() |
The Delta Controls Series 835 detects the presence or absence of material at the elevation of its probe. The arriving material pushes the lower end of the hanging probe to one side. An internal drop of liquid acts as a tilt sensor and signals when the probe moves to an angle of 15° away from vertical. A variety of tilt probes are available for use in solids and liquids. Interconnecting cable integrity and electronics operation are continuously maintained
|
|
|
Data Sheets |
||